Description
The TEC-11 drain valve unit consists of a solid-state timer coupled to a solenoid valve and only requires a simple installation procedure. The unit is designed exclusively for ALL compressed air filters, regardless of their capacity or size.
Timer specification
- Interval time: 1-120 minutes, adjustable
- Discharge time: 2 seconds FIXED
- Manual TEST switch: Yes, micro switch
- Supply voltage: 230 VAC/DC, ±10%,50/60 Hz
- Current consumption: 4mA maximum
- Operating temperature: -40°F to 140°F
- Environmental protection: IP 65, NEMA 4 when installed
- Housing material: ABS plastic FR grade
- Connection: DIN 43650B
- Indicators: 1 LED (yellow)indicating ON; Bright lights for clearer indication of operating status.
Valve specification
- Type: 2/2 way direct acting
- In/out ports: 1/8 in. NPT Female
- Minimum/Maximum working pressure: 0-230 PSI
- Minimum/Maximum temperature: 35°F to 130°F ambient
- Media temperature: Maximum 190°F
- Valve body: Forged brass
- Insulation: Higher grade H coils. Industry standard is grade F. Grade H offers superior resistance to higher temperature and provides longer life.
- Environmental protection: IP 65 (NEMA 4)
- Mounting in any position: Yes